Water is one of the most important natural resources and it plays a very vital role in our life. All animals and plants need water to survive, it carries a lot of nutrients and minerals. It plays a great role to serve the domestic as well as industrial purposes. So, it is important to monitor the quality of water that we release from our homes/ industries and it is also important to keep a check on the quality of water we consume for domestic as well as industrial purposes. As water is required for different purposes, the suitability of it must be checked before use. Source of water must be monitored regularly to determine whether they are in sound health or not. Therefore, water quality analysis is essential for using it for any purpose.
The guidelines have been established to test the physical and chemical attributes of water. The testing of water helps to maintain the quality of water thereby safeguarding against environment and health risks.
Our laboratory performs various tests on water to check the quality for suitability of the construction, drinking and other industrial as well as domestic purpose.
The experts of our laboratory are always ready to provide consultancy and testing services over a wide range of scope.
We perform the testing services to check whether the quality is in compliance with standards and suitable for designated use or not. Our lab helps to check whether upgradation/ change of an existing system is required and to decide what changes should take place. Our expertise in this field include highly experienced scientists and engineers to determine whether the water quality is in compliance with rules and regulations and perform deep quality analysis to serve the public health sector (especially for drinking water) and industrial purpose.
With comprehensive equipment and team of professionals we have the potential to make substantial impact regarding testing precision of water. We perform all the testing services under the strict guidelines of NABL 17025 and ISO 9001. With our well thought policies we are always ready to serve the industrial sector, government agencies and individual clients.
Water for construction purpose, Drinking Water.
Sr. No | Product/Material of Test | Specific Test Performed | Test method | Test Performed at |
---|---|---|---|---|
1 | Water for Construction Purpose | Acidity As Volume of 100ml sample used neutralize 0.02N NaOH, Using Phenolphthalein indicator Test | IS 3025 (P-22) RA-2014: 1986 | Permanent Facility |
2 | Water for Construction Purpose | Alkalinity as volume of 100ml sample used neutralize 0.02N H2SO4, Using Mix indicator Test | IS 3025 (P-23) RA-2014: 1986 | Permanent Facility |
3 | Water for Construction Purpose | Chloride Test | Is 3025 (P-32) Ra 2014: 1988 | Permanent Facility |
4 | Water for Construction Purpose | Inorganic Material Test | IS 3025 (P-18) RA-2012: 1984 | Permanent Facility |
5 | Water for Construction Purpose | Organic Material Test | IS 3025 (P-18) RA-2012: 1984 | Permanent Facility |
6 | Water for Construction Purpose | PH Test | IS 3025 (P-11) RA-2012: 1983 | Permanent Facility |
7 | Water for Construction Purpose | Sulphate as SO3 Test | IS 3025 (P-24) RA-2014: 1986 | Permanent Facility |
8 | Water for Construction Purpose | Total Dissolve Test | IS 3025 (P-16) RA-2012: 1984 | Permanent Facility |
9 | Water for Construction Purpose | Total Suspended Solid Test | IS 3025 (P-17) RA-2012: 1986 | Permanent Facility |
10 | Drinking Water | Acidity as CaCo3 Test | IS 3025 (P-22) RA-2014: 1986 | Permanent Facility |
11 | Drinking Water | Acidity as Volume of 100ml sample used Neutralize 0.02N NaOH, Using Phenolphthalein indicator Test | IS 3025 (P-22) RA-2014: 1986 | Permanent Facility |
12 | Drinking Water | Alkalinity as CaCo3 Test | IS 3025 (P-23) RA-2014: 1986 | Permanent Facility |
13 | Drinking Water | Alkalinity as volume of 100ml sample used Neutralize 0.02N H2SO4, Using Mix indicator Test | IS 3025 (P-23) RA-2014: 1986 | Permanent Facility |
14 | Drinking Water | Arsenic Test | IS 3025 (P-37) RA-2014: 1988 | Permanent Facility |
15 | Drinking Water | Calcium Test | IS3025 (P-40) RA-2014: 1988 | Permanent Facility |
16 | Drinking Water | Chloride Test | IS 3025 (P-32) RA-2014: 1988 | Permanent Facility |
17 | Drinking Water | Conductivity Test | IS 3025 (P-14) RA-2013: 1984 | Permanent Facility |
18 | Drinking Water | Fluoride Test | IS 3025 (P-60) RA-2014: 2008 | Permanent Facility |
19 | Drinking Water | Inorganic Material Test | IS 3025 (P-18) RA-2012: 1984 | Permanent Facility |
20 | Drinking Water | Iron Test | IS 3025 (P-53) RA-2014: 2003 | Permanent Facility |
21 | Drinking Water | Magnesium Test | IS 3025 (P-46) RA-2014: 1994 | Permanent Facility |
22 | Drinking Water | Odour Test | IS 3025 (P-5) : 1983 | Permanent Facility |
23 | Drinking Water | Organic Material Test | IS 3025 (P-18) RA-2012: 1984 | Permanent Facility |
24 | Drinking Water | PH Test | IS 3025 (P-11) RA-2012: 1983 | Permanent Facility |
25 | Drinking Water | Phosphorus Test | IS 3025 (P-31) RA-2014: 1988 | Permanent Facility |
26 | Drinking Water | Phosphorus Test | IS 3025 (P-31) RA-2014: 1988 | Permanent Facility |
27 | Drinking Water | Sulphate as So3 Test | IS 3025 (P-24) RA-2014: 1986 | Permanent Facility |
28 | Drinking Water | Taste | IS 3025 (P-7&8): 1984 | Permanent Facility |
29 | Drinking Water | Total Dissolve Test | IS 3025 RA-2012: 1984 | Permanent Facility |
30 | Drinking Water | Total Hardness as CaCo3 Test | IS 3025 (P-21) RA 2014: 2009 | Permanent Facility |
31 | Drinking Water | Total Suspended Solid Test | IS 3025 (P-17) RA-2012: 1984 | Permanent Facility |
32 | Drinking Water | Turbidity Test | IS 3025 (P-10) RA-2012: 1984 | Permanent Facility |